Side-Power 8981 Manuál s instrukcemi Strana 15

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 14
8981FS Instruction Manual 9
Conguration
Configuration
This section describes:
Onboard conguration hardware (switches and LEDs),
Module operation modes and appropriate setups,
Using the onboard switches to make conguration settings, and
Remote conguration and monitoring using the 8900NET interface.
Configuration Switches and LEDs
The 8981FS module can be congured locally using the onboard rotary and
toggle switches shown in Figure 5. Two LEDs are used to indicate status of
the conguration process. These four components perform the following:
Function (rotary) switch – addresses a desired function for congura-
tion and provides two sets (banks) of 16 functions (0 through 9, A
through F), although not all positions are used.
Note
The Function switch should be kept in position 0 or F when not in use to avoid
any inadvertent change in conguration. 0 and F are inactive positions.
2nd FUNC (second function) LED – when on, indicates that the rotary
switch is addressing the second bank (Bank 2) of functions (see Table 3
on page 15).
SW1 (toggle) switch – actuates or selects the desired setting for the
selected function when the switch is pushed momentarily in either the
Up or Down position.
CONF (conguring) LED – when on, indicates the module is initial-
izing or processing conguration information.
Note
Function switch position E (Restore) in Bank 2 can be used to return the
module conguration to the factory default (as shown in Table 3 on page 15).
Conguration can also be performed using the 8900NET with GUI. Remote
control can, however, be locked out using the jumper (J5) shown in Table 5
on page 10.
Zobrazit stránku 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 37 38

Komentáře k této Příručce

Žádné komentáře